The AC600-X Multi-Channel Power Analyzer delivers reliable, professional-grade performance. It achieves 0.1 % voltage and current accuracy, with measurement bandwidth from 0.5 Hz to 100 kHz. The maximum voltage is 1000 Vrms, and the maximum current options include 50 A, 20 A, 10 A, 5 A, 2 A, and 1 A. Mixed-range configuration is supported, and external sensors are available as an option. It is widely used to measure parameters such as voltage, current, power, frequency, and harmonics of single-phase electrical equipment.
| Model | Voltage | Current | Accuracy | Interface | Size | Inquiry | |
|---|---|---|---|---|---|---|---|
| AC600-X | 1000Vrms | 50A/20A/10A/5A/2A/1A | ±0.1% | RS-232 / Digital I/O / RS-485 | 3U | ||
| No models match the selected filters | |||||||
*Specifications for the product series are subject to change without notice.
• Multi‑channel: Configurable with 1‑6 measurement units, supporting flexible operation modes including multi‑channel single‑phase, 2×3P3W, 2×3P4W and 4‑phase (DC + 3P3W), meeting measurement requirements for various loads such as air conditioners, inverters, frequency converters and motors.
• High Accuracy: High-speed DSP processor and 16-bit high-speed, high-precision AD converter; basic accuracy up to 0.1 %; minimum data update cycle of 100 ms
• Wide power measurement range: Single channel measurable current up to 50 A (20 A, 10 A, 5 A, 2 A, 1 A variants optional; mixed‑range configuration supported). Minimum power resolution of 0.1 mW, covering both standby power consumption and rated power measurement requirements
• Wide bandwidth: supports both AC and DC signals; power measurement bandwidth DC, 0.5 Hz ~ 100 kHz. Suitable for power measurement of loads with standard and non-standard sinusoidal waveforms
• Frequency measurement: Six channels support simultaneous frequency measurement.
• Line filtering: built‑in 500 Hz and 5.5 kHz low‑pass filters for measuring fundamental values of PWM waveforms and suppressing high‑frequency current interference from switching power supplies
• Sensors: ratio setting function, compatible with conventional I-I and V-V voltage/current transformers; supports I-V current sensors with a BNC interface, with maximum input voltage of 10 V. High-current sensors are available as an option
• Efficiency Calculation: Simultaneously measures input and output energy consumption of the DUT and calculates its efficiency
• Energy Accumulation: Supports independent accumulation of forward, reverse, and total energy for billing and net‑metering applications
• Threshold alarm: Independent threshold and limit‑value configuration for voltage, current, power, power factor on each channel; automatic upper/lower‑limit detection with alarm triggering
• Bilingual Interface: Switchable Chinese/English user interface
Main Functions
Single‑channel measurement
| Peak detection
|
Energy measurement
| Efficiency measurement
|
Three‑phase measurement
| Six‑Channel Measurement
|
Channel Configuration
The Multi-Channel Power Analyzer supports multiple wiring configurations, including 1P2W, 1P3W, 3P3W, 3V3A, and 3P4W. Users can configure multi-channel modes according to application requirements to measure voltage, current, power, efficiency, and other parameters of various loads.
Wiring Configuration | Channel 1 | Channel 2 | Channel 3 | Channel 4 | Channel 5 | Channel 6 |
1P2W (Single-phase Two-wire) | 1P2W | 1P2W | 1P2W | 1P2W | 1P2W | 1P2W |
1P3W(Single-phase Three-wire) | 1P3W | 1P3W | ||||
3P3W(Three-phase Three-wire) | 3P3W | 3P3W | ||||
3V3A (Three-phase Three-wire) | 3V3A | 3V3A | ||||
3P4W(Three-phase Four-wire) | 3P4W | 3P4W | ||||
Product Applications
• PV Inverter Power Measurement
• Complies with CGC/CF 004‑2011 and CNCA/CTS 0004‑2009A standards
• Voltage range: 0‑1500 V
• Current range: 0–50 A / current sensor input
• Simultaneous measurement of input and output (single‑phase / three‑phase) power and power factor
• Automatic efficiency calculation
• Bidirectional power measurement for energy buy‑sell applications

Wiring Configuration | Channel 1 | Channel 2 | Channel 3 | Channel 4 | Channel 5 | Channel 6 |
Single-Phase PV Inverter | 1P2W DC | 1P2W AC | 1P2W | 1P2W | 1P2W | 1P2W |
Three-Phase PV Inverter | 3P3W/3V3A/3P4W AC | 1P2W DC | 1P2W | 1P2W | ||
• Power Measurement for Variable-Frequency Motors and VFDs
• Compliance with GB 12668 standard
• Power measurement bandwidth: DC, 0.5 Hz–100 kHz
• Current range: 0–50 A / current sensor input
• Simultaneous measurement of input and output power
• Optional filter for carrier frequency rejection


Wiring Configuration | Channel 1 | Channel 2 | Channel 3 | Channel 4 | Channel 5 | Channel 6 |
frequency converter | 3P3W/3V3A/3P4W | 3P3W/3V3A/3P4W | ||||
• Charging Pile and Electric Vehicle Performance Measurement
• Multi-channel architecture enables simultaneous testing of multiple parameters: charging station performance, battery charge-discharge performance, power conversion performance, motor performance, and other parameters.
• AC/DC compatible, maximum current 50 A; higher‑current sensors available for expansion
• High accuracy: basic accuracy 0.1%, minimum power resolution 0.1 mW
• Measures instantaneous RMS, average, peak, energy, etc. for AC and DC signals

Wiring Configuration | Channel 1 | Channel 2 | Channel 3 | Channel 4 | Channel 5 | Channel 6 |
Charging Pile | 1P2W | 1P2W | 1P2W | 1P2W | 1P2W | 1P2W |
3P3W/3V3A/3P4W | 3P3W/3V3A/3P4W | |||||
Electric Vehicle | 1P2W | 1P2W | 1P2W | 1P2W | 1P2W | 1P2W |
• Transformer Power Measurement
• Power factor accuracy range down to 0.001
• Multi‑channel synchronized high‑speed sampling
• Power measurement bandwidth: DC, 0.5 Hz ~ 100 kHz
• Current range: 0 – 50 A / current sensor input
• Simultaneous measurement of input and output power

Wiring Configuration | Channel 1 | Channel 2 | Channel 3 | Channel 4 | Channel 5 | Channel 6 |
Transformer | 3P3W/3V3A/3P4W | 3P3W/3V3A/3P4W | ||||
• Power Supply and UPS Power Measurement
• Current range: 0 – 1 A / 2 A / 5 A / 10 A / 20 A / 50 A
• Power measurement bandwidth: DC, 0.5 Hz ~ 100 kHz
• Simultaneous measurement of input and output (single‑phase / three‑phase) power; monitors battery charge and discharge capacity
• Automatic efficiency calculation


Wiring Configuration | Channel 1 | Channel 2 | Channel 3 | Channel 4 | Channel 5 | Channel 6 |
Power Supply, UPS | 1P2W Mains Input | 1P2W Battery | 1P2W Battery | 3P3W/3V3A/3P4W Power Output | ||
• Home Appliance Performance Evaluation and Standby Power Measurement
• Complies with IEC 62301‑2011 standard
• Current range: 0 – 1 A / 2 A / 5 A / 10 A / 20 A / 50 A; supports rated power and standby power measurement
• Minimum power resolution: 0.1 mW
• Automatically identifies appliance operating, stop and standby states, and selectively accumulates energy


Wiring Configuration | Channel 1 | Channel 2 | Channel 3 | Channel 4 | Channel 5 | Channel 6 |
Household appliances | 1P2W | 1P2W | 1P2W | 1P2W | 1P2W | 1P2W |
Commercial appliances | 3P4W | 3P4W | ||||
• Lighting and LED Power Measurement
• Current range: 0 – 1 A / 2 A / 5 A / 10 A
• Minimum power resolution: 0.1 mW
• Measures input power, output power, power factor and efficiency of driver power supplies

Wiring Configuration | Channel 1 | Channel 2 | Channel 3 | Channel 4 | Channel 5 | Channel 6 |
Lighting | 1P2W | 1P2W | 1P2W | 1P2W | 1P2W | 1P2W |
Model | AC6500-x | |
Product Name | Multi-Channel Power Analyzer | |
Measurement Channels (x) | 1~6 | |
Wiring Configuration | 1P2W (Single-phase 2-wire), 1P3W (Single-phase 3-wire), 3P3W (3-phase 3-wire, 2 voltage, 2 current), 3P3W (3V3A) (3-phase 3-wire, 3 voltage, 3 current), 3P4W (3-phase 4-wire) | |
Measurement Parameters | Voltage (U), Current (I), Active Power (P), Reactive Power (Q), Apparent Power (S), Power Factor (PF), Voltage Frequency (fU), Current Frequency (fI), Phase Angle (Φ), Efficiency (η), Total Energy (Wh), Forward Energy (Wh+), Reverse Energy (Wh–), Current Integration (Ah), 50th Harmonic Analysis (HDF), Voltage and Current Total Harmonic Distortion (THD), Peak Voltage (Upk), Peak Current (Ipk), Voltage Crest Factor (CfU), Current Crest Factor (CfI), DC Voltage (Udc), DC Current (Idc), Average rectified value (Umn/Imn/Urmn/Irmn),Three-phase Parameters (Σ) | |
Input Impedance | Voltage: approx. 2 MΩ | |
Current Direct Input: Approx. 2.5 mΩ (50 A range); Current sensor input: approx. 100 kΩ | ||
A/D Sampling Rate | Approx. 100 kS/s | |
Full-Scale Crest Factor | 3 | |
*Exceptions noted below | ||
Voltage Rated Range | 15/30/60/100/150/300/600/1500*[V] | |
(Direct Input) | *Full-scale crest factor for 1500 V range is 1.5 | |
Rated Current Range | 50A model:500m/1/2/5/10/20/40/50*[A] | |
Optional: | ||
20 A model:100m/200m/500m/1/2/5/10/20*[A] | ||
10 A model:50m/100m/200m/500m/1/2/5/10*[A] | ||
5 A model:20m/50m/100m/200m/500m/1/2/5*[A] | ||
2 A model:10m/20m/50m/100m/200m/500m/1/2*[A] | ||
1 A model:5m/10m/20m/50m/100m/200m/500m/1*[A] | ||
*Full-scale crest factor for the maximum range of the above models is 1.5 | ||
Current Rated Ranges | 50m/100m/200m/500m/1/2/5/10[V] | |
(Sensor Input) | ||
Voltage/Current | (1%~110%)*×Range | |
Accuracy Range | *For 1500V voltage range and 50A current range: (1% to 100%) × Range | |
Power Factor | ±(0.001 ~ 1.000) | |
Accuracy Range | ||
Voltage Measurement Accuracy | DC | ±(0.1%× indicating value+0.1%× range) |
0.5Hz≤f<45Hz | ±(0.1%× indicating value+0.2%× range) | |
45Hz≤f≤66Hz | ±(0.1%× indicating value+0.1%× range) | |
66Hz<f≤1kHz | ±(0.1%× indicating value+0.2%× range) | |
1kHz<f≤10kHz | ±({0.1+0.05×(f-1)}%× indicating value+0.2%× range) | |
10kHz<f≤100kHz | ±({0.5+0.04×(f-10)}%× indicating value+0.3%× range) | |
Current Measurement Accuracy | DC | ±(0.1%× indicating value+0.1%× range) |
0.5Hz≤f<45Hz | ±(0.1%× indicating value+0.2%× range) | |
45Hz≤f≤66Hz | ±(0.1%× indicating value+0.1%× range) | |
66Hz<f≤1kHz | ±(0.1%× indicating value+0.2%× range) | |
1kHz<f≤10kHz | ±((0.1×f)% indicating value+0.2%× range) | |
10kHz<f≤100kHz | ±({1+0.08×(f-10)}%× indicating value+0.3%× range) | |
Active Power Measurement Accuracy | DC | ±(0.1%× indicating value+0.1%× range) |
0.5Hz≤f<45Hz | ±(0.3%× indicating value+0.2%× range) | |
45Hz≤f≤66Hz | ±(0.1%× indicating value+0.1%× range) | |
66Hz<f≤1kHz | ±(0.2%× indicating value+0.2%× range) | |
1kHz<f≤10kHz | ±({0.2+0.1×(f-1)}%× indicating value+0.2%× range) | |
10kHz<f≤50kHz | ±({0.2+0.1×(f-1)}%× indicating value+0.3%× range) | |
50kHz<f≤100kHz | ±({5.1+0.18×(f-50)}%× indicating value+0.3%× range) | |
Active Power Measurement Range | 50A model:11mW~11kW@220V,PF=0.01~1 | |
Optional models: | ||
20A model:2.2mW~4.4kW@220V,PF=0.01~1 | ||
10A model:1.1mW~2.2kW@220V,PF=0.01~1 | ||
5A model:0.4mW~1.1kW@220V,PF=0.01~1 | ||
2A model:0.2mW~440W@220V,PF=0.01~1 | ||
1A model:0.1mW~220W@220V,PF=0.01~1 | ||
Low Power Factor | Apparent power measurement accuracy: ±(0.2% indicating value) @ PF = 0 | |
Power Accuracy Range | Active power accuracy: add 0.05%@PF=0.001~0.1 | |
Maximum Active | 0.1mW | |
Power Resolution | ||
Frequency Measurement Range | DC,0.5Hz ~ 100kHz | |
Frequency Measurement Accuracy | ±0.1%× indicating value | |
Harmonic Measurement | 10Hz ~ 600Hz,1st to 50th harmonic content, total harmonic distortion | |
Energy Measurement Range | 0~999999MWh (Resolution: 1mWh/0.01mAh) | |
Energy Measurement Accuracy | ±0.2%× indicating value | |
Expanded Uncertainty | Voltage, current, power, frequency, energy ≤ 0.20% | |
Filter Function | 500Hz、5.5kHz voltage-line, current-line and frequency filtering | |
Transformation Ratio Range | 1 ~ 50000 | |
Data Update Cycle | 100m / 250m / 500m / 5[s] | |
Alarm Functions | Voltage, current, power, power factor; upper limit, lower limit, threshold setting | |
Control Interfaces | Standard: RS-232, Digital I/O Interface; | |
Display | 7-inch widescreen color LCD touchscreen | |
Overall Dimensions(W×H×D) | 426(W, excluding mounting ears) x 132.5(H, excluding feet) x 484(D, excluding terminals) mm | |
Foot Height | 14.5 mm | |
Terminal Depth | 32.5 mm(current terminals) | |
Net Weight | 约10 kg | |