Home You are here: Home - Products - Electrical Safety Analyzer - Internal Resistance Tester

AC3560 Series
Internal Resistance Tester

The AC3560 Series 6½-digit high-resolution internal resistance tester is a battery internal resistance tester featuring high accuracy and fast measurement, with a voltage measurement range of 0 V to 2000 V. It uses the AC four-terminal measurement method for more accurate measurement of battery internal resistance and voltage. It delivers a resistance resolution of 0.1 μΩ and voltage resolution ranging from 1 μV to 10 μV. Standard interfaces include RS-232/485, LAN, EXT I/O, USB Device, and Analog Output to support various test scenarios. The built‑in comparator capability automatically determines whether battery parameters meet specification requirements. With straightforward operation, high accuracy, high-speed measurement, and reliable stability, this series of battery internal resistance testers offers a reliable testing solution.

Applications:

Featuring high accuracy and high speed, it is suitable for various battery types and a wide range of test scenarios.

Model

Model Voltage Resistance Voltage Resolution Interface Size Inquiry
AC3561A 0~110V 0~3600Ω 1μV RS232/485,LAN,EXT I/O,USB Device,Analog Output -
AC3562A 0~210V 0~3600Ω 1μV RS232/485,LAN,EXT I/O,USB Device,Analog Output -
AC3563A 0~360V 0~3600Ω 1μV RS232/485,LAN,EXT I/O,USB Device,Analog Output -
AC3564A 0~1100V 0~3600Ω 10μV RS232/485,LAN,EXT I/O,USB Device,Analog Output -
AC3565A 0~1600V 0~3600Ω 10μV RS232/485,LAN,EXT I/O,USB Device,Analog Output -
AC3566A 0~2000V 0~3600Ω 10μV RS232/485,LAN,EXT I/O,USB Device,Analog Output -
No models match the selected filters

*Specifications for the product series are subject to change without notice.

Product Features

• 6½-digit high-resolution internal resistance tester with high accuracy and high-speed measurement; voltage measurement range: 0–1100 V.

• Resistance resolution: 0.1 μΩ; voltage resolution: 1 μV ~ 10 μV. It provides high accuracy and high-speed performance, and is compatible with various battery types.

• Standard interfaces: RS‑232/485, LAN, EXT I/O, USB Device, and Analog Output, suitable for diverse test scenarios.

• It uses the AC four‑terminal test method. Impedance measurements are unaffected by test‑lead impedance.

• Features independent comparator capabilities for resistance and voltage; battery internal resistance and voltage can be displayed simultaneously.

• Short-circuit zero adjustment capability eliminates errors originating from instrument offset voltage and measurement environment.

• Supports screenshot saving to a USB flash drive; instrument firmware can be upgraded via a USB flash drive.

• Sampling rate: Slow / Medium / Fast. The fastest high-speed measurement takes approx. 40 ms.

• Generates normal‑distribution charts for intuitive review of the normal‑distribution status of measurement results.

• Measurement results can be easily saved to a USB flash drive for subsequent data analysis and processing.


Dimensions

Model

AC3561A

AC3562A

AC3563A

AC3564A

AC3565A

AC3566A

Resistance

Range

3mΩ/30mΩ/300mΩ/3Ω/30Ω/300Ω/3600Ω

Measurement Range

0~3600Ω

Minimum Resolution

0.1μΩ

Voltage

Measurement Range

0~110V

0~210V

0~360V

0~1100V

0~1600V

0~2000V

Minimum Resolution

1μV

1μV

1μV

10μV

10μV

10μV

Input Power Specification

90~240 VAC;47~63Hz; 30VA

Input Impedance

3mΩ~3600Ω  10MΩ

Open-terminal Voltage

3mΩ~3600Ω  15V peak

Test Fault Indication

Detection Items: SOURCE HIGH-LOW connection abnormal;

(Contact Detection)

SENSE HIGH-LOW connection abnormal. Display: [-----]

Sampling

Sampling Rate

Fast / Medium / Slow (3-speed modes)

Sampling Time

Function

Frequency

Fast

Medium

Slow

ΩV

50Hz/60Hz

60ms

300ms

600ms

Ω

50Hz/60Hz

40ms

200ms

400ms

V

50Hz/60Hz

40ms

200ms

400ms

Time

Response Time

Measurement Response Time:  Approx. 5 ms

Total Measurement Time

Total Measurement Time:  Sampling Time + Response Time

Comparator Function Module

Comparator Function

ON / OFF (shared for resistance and voltage)

Comparator Settings

Comparator Mode: HIGH-LOW / REF-%

Upper / Lower Limit: 0 ~ 3600 Ω (Resistance) / 0 ~ 2000 V (Voltage)

Reference Value: 0 ~ 3600 Ω (Resistance) / 0 ~ 2000 V (Voltage)

% Value: 0.000 % ~ 99.99 % (% range supports ± tolerance)

Buzzer Mode: OFF / HL / IN / BT1 / BT2

Compare Mode: Auto / Manual

Judgment

Judgment Result:Hi / In / Lo (Resistance and Voltage judged independently)

PASS / UNPASS Judgment:AND operation on resistance judgment result and voltage judgment result,

then output PASS/UNPASS (EXT I/O output)

Abnormal Test Value Judgment:OF----Hi judgment;

-OF----- Lo  judgment;

Test Abnormality------No judgment (judgment disabled)

Absolute Value Judgment Function

Allows comparison based on absolute value even if battery polarity is reversed

Average Function

Outputs averaged measurement value to reduce display deviation; averaging count: 1, 2, 4, 8

Delay Time

0 ~ 9999 ms

Calibration

Voltage Calibration / Resistance Calibration, used to compensate for internal offset voltage or gain drift of the instrument

Zero Adjustment Range

Resistance measurement: -1000 ~ 1000 counts;

Voltage measurement: -1000 ~ 1000 counts (adjustable zero range ≤ ±1000 dgt.)

Trigger

Internal / External / Manual

Current Output

Pulse / Continuous

Storage

ON / OFF / CLEAR; measurement values can be saved to a USB flash drive via key or command

Statistics

Statistical Calculation

 ON / OFF / CLEAR

Calculation Items

Mean, maximum, minimum, population standard deviation, sample standard deviation, process capability index (offset), process capability index (deviation), etc.

Calculation Trigger

Perform statistical calculation on measured values via keys or commands

Setup Save and Recall

Function

Save and recall measurement settings

Saved Settings

Measurement type, Resistance range, Voltage range, Auto-range setting, Sampling rate, Trigger source, Absolute value, Delay setting, Average setting, Comparator setting, Statistical calculation setting, Communication setting

Key Beep

 ON / OFF

Communication Interfaces

AC3000 Series: RS232/485; USB; LAN; I/O Analog Output interface

* Due to layout limitations, only best‑selling models are shown.Contact us for a complete product selection.



Product Documentation

1
AC3560 Series Internal Resistance Tester
Chat Inquiry Contact E-mail
TOP

Product Catalog