The BSC67 Series adopts active power factor correction and high-frequency LLC multi-resonant soft-switching inverter technologies. It features high power factor, fast dynamic response, low output ripple, and high power density. The standard 19-inch 3U chassis delivers up to 18 kW, with efficiency up to 93%. The BSC67 Series provides eight voltage levels covering 0–2400 V and supports multi-unit parallel operation. It includes a built-in function generator that generates various user-defined waveforms, delivering superior performance and comprehensive test functions.
| Model | Voltage | Current | Power | Accuracy | Interface | Size | Inquiry |
|---|---|---|---|---|---|---|---|
| BSC6780-170 | 80V | 170A | 5kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC6780-340 | 80V | 340A | 10kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC6780-510 | 80V | 510A | 15kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC67200-120 | 200V | 120A | 6kW | ≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC67200-240 | 200V | 240A | 12kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC67200-360 | 200V | 360A | 18kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC67300-75 | 300V | 75A | 6kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC67300-150 | 300V | 150A | 12kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC67300-225 | 300V | 225A | 18kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC67500-40 | 500V | 40A | 6kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC67500-80 | 500V | 80A | 12kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC67500-120 | 500V | 120A | 18kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC67800-25 | 800V | 25A | 6kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC67800-50 | 800V | 50A | 12kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC67800-75 | 800V | 75A | 18kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC671000-20 | 1000V | 20A | 6kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC671000-40 | 1000V | 40A | 12kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC671000-60 | 1000V | 60A | 18kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC671500-25 | 1500V | 25A | 12kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC671500-40 | 1500V | 40A | 18kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| BSC672400-25 | 2400V | 25A | 18kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/RS485/CAN |
3U | |
| No models match the selected filters | |||||||
*Specifications for the product series are subject to change without notice.
• Features active PFC, delivering a power factor of up to 0.99.
• Adjustable output voltage and current slew rates.
• Offers wide‑range output capability, with its output range 3 times greater than matrix power supplies of an identical power rating.
• Utilizes a high‑frequency LLC multi‑resonant inverter, achieving overall unit efficiency of up to 93%.
• Master-slave mode supports parallel operation with active current sharing for multi-unit paralleling.
• Optional PV simulation function, controllable via host PC software.
• Features built‑in OVP, OCP, OPP and OTP protection, as well as reverse‑connection protection for SENSE terminals.
• Features remote‑sense terminals for lead‑voltage‑drop compensation during high‑current operation.
• Built-in function generator.
• Comes with an integrated discharge circuit (Uout < 10 V within 1 s).
• Equipped with multiple communication interfaces, including RS232, RS485, LAN and CAN.
• High-brightness color LCD display; intuitive and straightforward operation with an elegant design.
Wide‑Range Output
Constant-power power supplies provide broader output voltage and current ranges than conventional power supplies. A single model can satisfy test requirements for multiple product specifications. Its output voltage and current are constrained by maximum power: higher output voltage is available at lower output current, and higher output current can be achieved at reduced output voltage. This design delivers higher operational flexibility than traditional matrix power supplies.
Example: BSC6780-170 (see figure below)

PV Simulation Function
The power supply supports PV simulation, with configurable parameters including VOC, ISC, VMP, IMP, and FF. It also provides PV characteristic I-V curve simulation, enabling realistic simulation of various solar cell types under different environmental conditions, and supports standard curves such as EN50530 and SAS. Dynamic PV simulation testing is also supported.
Power Supply Interface

Host PC Software Interface



Model | BSC6780-170 | BSC6780-340 | BSC6780-510 | BSC67200-120 | BSC67200-240 | BSC67200-360 | |
AC Input | Phase | 3-phase 3-wire + PE | |||||
Voltage | 380VAC±10% | ||||||
Frequency | 47~63Hz | ||||||
Power Factor | ≥0.99 | ||||||
DC Output | Voltage | 0~80V | 0~200V | ||||
Current | 0~170A | 0~340A | 0~510A | 0~120A | 0~240A | 0~360A | |
Power | 0~5kW | 0~10kW | 0~15kW | 0~6kW | 0~12kW | 0~18kW | |
Efficiency | ≤93% | ||||||
Programming Accuracy | Voltage | ≤±(0.03%+0.02%FS) | |||||
Current | ≤±(0.05%+0.05%FS) | ||||||
Power | ≤±0.4%FS | ||||||
Readback Accuracy | Voltage | ≤±(0.03%+0.02%FS) | |||||
Current | ≤±(0.05%+0.05%FS) | ||||||
Power | ≤±0.4%FS | ||||||
Ripple & Noise | RMS | 20mVrms | 40mVrms | ||||
(20Hz-300kHz) | |||||||
P-P | 250mVpp | 250mVpp | |||||
(20Hz-20MHz) | |||||||
Source Effect | Voltage | ≤0.02%FS (±10%ΔUACInput) | |||||
Current | ≤0.05%FS (±10%ΔUACInput) | ||||||
Load Effect | Voltage | ≤0.05%FS(0-100% Load Regulation) | |||||
Current | ≤0.15%FS(0-100%ΔUDC Load Regulation) | ||||||
Analog Interface (Optional) | Specifications | Built-in 15-pin D-Sub female connector, electrically isolated | |||||
Signal Range | 0~5V or 0~10V (switchable) | ||||||
U / I / P Accuracy | 0~10V: ≤0.2%FS | ||||||
Dynamic Response Time | LoadRegulating Settling Time | ≤2ms(Load change: 10-100%) | |||||
Output Voltage Rise Time | 10ms(10–90% of full scale) | ||||||
Protection Functions | OTP ,OVP ,OCP ,OPP ,PF | ||||||
Communication Interfaces | Standard: RS232 + LAN Optional: RS485, CAN | ||||||
Operating Environment | Operating Temperature: 0~50°C, Humidity: <80%, non-condensing;Storage Temperature: -20~70°C, Altitude: <2000m | ||||||
Isolation Withstand Voltage | 1000VDC(Output to Earth Ground) | ||||||
Dimensions (W×D×H, mm) | 482×670×132 | 482mm×670mm×132mm | |||||
Packaging Dimensions (W×D×H, mm) | 885×685×285 | 885×685×285 | |||||
Weight /Gross Weight | 26.2kg/31.25kg | 35.55kg/40.6kg | 44.87kg/49.9kg | 25.9kg/30.9kg | 35.25kg/40.3kg | 44.5kg/49.55kg | |
Model | BSC67300-75 | BSC67300-150 | BSC67300-225 | BSC67500-40 | BSC67500-80 | BSC67500-120 | |
AC Input | Phase | 3-phase 3-wire + PE | |||||
Voltage | 380VAC±10% | ||||||
Frequency | 47~63Hz | ||||||
Power Factor | ≥0.99 | ||||||
DC Output | Voltage | 0~300V | 0~500V | ||||
Current | 0~75A | 0~150A | 0~225A | 0~40A | 0~80A | 0~120A | |
Power | 0~6kW | 0~12kW | 0~18kW | 0~6kW | 0~12kW | 0~18kW | |
Efficiency | ≤93% | ||||||
Programming Accuracy | Voltage | ≤±(0.03%+0.02%FS) | |||||
Current | ≤±(0.05%+0.05%FS) | ||||||
Power | ≤±0.4%FS | ||||||
Readback Accuracy | Voltage | ≤±(0.03%+0.02%FS) | |||||
Current | ≤±(0.05%+0.05%FS) | ||||||
Power | ≤±0.4%FS | ||||||
Ripple & Noise | RMS | 40mVrms | 50mVrms | ||||
(20Hz-300kHz) | |||||||
P-P | 250mVpp | 325mVpp | |||||
(20Hz-20MHz) | |||||||
Source Effect | Voltage | ≤0.02%FS (±10%ΔUACInput) | |||||
Current | ≤0.05%FS (±10%ΔUACInput) | ||||||
Load Effect | Voltage | ≤0.05%FS(0-100% Load Regulation) | |||||
Current | ≤0.15%FS(0-100%ΔUDC Load Regulation) | ||||||
Analog Interface (Optional) | Specifications | Built-in 15-pin D-Sub female connector, electrically isolated | |||||
Signal Range | 0~5V or 0~10V (switchable) | ||||||
U / I / P Accuracy | 0~10V: ≤0.2%FS | ||||||
Dynamic Response Time | Load-Regulating Settling Time | ≤2ms(Load change: 10-100%) | |||||
Output Voltage Rise Time | 10ms(10–90% of full scale) | ||||||
Protection Functions | OTP ,OVP ,OCP ,OPP ,PF | ||||||
Communication Interfaces | Standard: RS232 + LAN Optional: RS485, CAN | ||||||
Operating Environment | Operating Temperature: 0~50°C, Humidity: <80%, non-condensing;Storage Temperature: -20~70°C, Altitude: <2000m | ||||||
Isolation Withstand Voltage | 1000VDC(Output to Earth Ground) | ||||||
Dimensions (W×D×H, mm) | 482mm×670mm×132mm | ||||||
Packaging Dimensions (W×D×H, mm) | 885×685×285 | 885×685×285 | |||||
Weight /Gross Weight | 25.9kg/30.9kg | 35.25kg/40.3kg | 44.5kg/49.55kg | 25.9kg/30.9kg | 35.25kg/40.3kg | 44.5kg/49.55kg | |
Model | BSC67800-25 | BSC67800-50 | BSC67800-75 | BSC671000-15 | BSC671000-30 | BSC671000-45 | BSC671500-25 | BSC671500-40 | BSC672250-25 | |
AC Input | Phase | 3-phase 3-wire + PE | ||||||||
Voltage | 380VAC±10% | |||||||||
Frequency | 47~63Hz | |||||||||
Power Factor | ≥0.99 | |||||||||
DC Output | Voltage | 0~800V | 0~1000V | 0~1500V | 0~2250V | |||||
Current | 0~25A | 0~50A | 0~75A | 0~15A | 0~30A | 0~45A | 0~25A | 0~40A | 0~25A | |
Power | 0~6kW | 0~12kW | 0~18kW | 0~6kW | 0~12kW | 0~18kW | 0~12kW | 0~18kW | 0~18kW | |
Efficiency | ≤93% | |||||||||
Programming Accuracy | Voltage | ≤±(0.03%+0.02%FS) | ||||||||
Current | ≤±(0.05%+0.05%FS) | |||||||||
Power | ≤±0.4%FS | |||||||||
Readback Accuracy | Voltage | ≤±(0.03%+0.02%FS) | ||||||||
Current | ≤±(0.05%+0.05%FS) | |||||||||
Power | ≤±0.4%FS | |||||||||
Ripple & Noise | RMS | 50mVrms | 100mVrms | 150mVrms | 225mVrms | |||||
(20Hz-300kHz) | ||||||||||
P-P | 325mVpp | 650mVpp | 975mVpp | 1460mVpp | ||||||
(20Hz-20MHz) | ||||||||||
Source Effect | Voltage | ≤0.02%FS (±10%ΔUACInput) | ||||||||
Current | ≤0.05%FS (±10%ΔUACInput) | |||||||||
Load Effect | Voltage | ≤0.05%FS(0-100% Load Regulation) | ||||||||
Current | ≤0.15%FS(0-100%ΔUDC Load Regulation) | |||||||||
Analog Interface (Optional) | Specifications | Built-in 15-pin D-Sub female connector, electrically isolated | ||||||||
Signal Range | 0~5V or 0~10V (switchable) | |||||||||
U / I / P Accuracy | 0~10V: ≤0.2%FS | |||||||||
Dynamic Response Time | LoadRegulating Settling Time | ≤2ms(Load change: 10-100%) | ||||||||
Output Voltage Rise Time | 10ms(10–90% of full scale) | |||||||||
Protection Functions | OTP ,OVP ,OCP ,OPP ,PF | |||||||||
Communication Interfaces | Standard: RS232 + LAN Optional: RS485, CAN | |||||||||
Operating Environment | Operating Temperature: 0~50°C, Humidity: <80%, non-condensing;Storage Temperature: -20~70°C, Altitude: <2000m | |||||||||
Isolation Withstand Voltage | 1000VDC(Output to Earth Ground) | |||||||||
Dimensions (W×D×H, mm) | 482mm×670mm×132mm | |||||||||
Packaging Dimensions (W×D×H, mm) | 885×685×285 | |||||||||
Weight /Gross Weight | 25.9kg/30.9kg | 35.25kg/40.3kg | 44.5kg/49.55kg | 25.9kg/30.9kg | 35.25kg/40.3kg | 44.5kg/49.55kg | 25.9kg/30.9kg | 35.25kg/40.3kg | 44.5kg/49.55kg | |