The EOL Comprehensive Test System is used to test comprehensive performance, such as insulation withstand voltage and BMS communication, of finished and semi-finished battery packs. The host PC software is developed on the ASP.NET platform. Featuring powerful data processing capabilities and high stability, it saves test data to the database in real time and uploads the data to the MES system.
• Modular overall design for high stability and reliability, with ease of maintenance and upgrades
• A high‑performance ARM main‑control chip ensures smooth and stable device operation.
• The host PC software features a concise, clear user interface. The test step sequence is editable, and test parameters are adjustable.
• It delivers high sampling accuracy for voltage and current, paired with excellent long‑term stability.
• Supports 1D barcodes and QR codes; test initiation is available via barcode scanning or foot‑switch trigger.
• Test data can be saved automatically. The robust database enables efficient quality traceability.
Basic Test Flow

Product Design Block Diagram

System Test Items
Basic Functions | |
1. Open-Circuit Voltage (OCV) | The battery-pack voltage measured by the instrument while the battery pack is neither charged nor discharged. |
2. AC Internal Resistance (ACIR) | The battery AC internal resistance is measured using the four-wire method. A sinusoidal current signal (1 kHz, ≤100 mA constant current) is injected through the positive and negative terminals of the battery pack, and the AC impedance is accurately measured through voltage sampling, rectification, filtering, and related processing. |
3. Trigger Start | Connect to the production line or other equipment. After the PLC or control board at the line's master control end issues a start command, the EOL test system begins operation. |
4. Scan-to-Start (Barcode Recording) | Start the equipment by scanning 1D or 2D barcodes to enhance convenience and smart operation. The scanned barcode is saved to the database together with the test results for later query and traceability. |
5. Insulation Resistance (Battery Pack Positive Terminal vs. Housing) | Insulation resistance refers to the resistance between the live part and the exposed part of the DUT. To avoid leakage accidents, the insulation test voltage must be high enough. This item tests the insulation resistance between the battery pack positive terminal and the battery housing. |
6. Insulation Resistance (Battery Pack Negative Terminal vs. Housing) | This item tests the insulation resistance between the battery pack negative terminal and the battery housing. |
7. AC Withstand Voltage / Leakage Current (Battery Pack Positive Terminal vs. Housing) | Excessively high leakage current may cause electric shock hazards to personnel. Withstand voltage and leakage current testing is a critical safety test item. |
Test Principle: Apply high voltage to the unit under test and detect the resulting leakage current. The withstand voltage and leakage current performance complies with specifications if the measured leakage current falls within the specified limits. | |
This item evaluates the AC withstand voltage performance between the positive terminal of the battery pack and the battery housing. | |
8. AC Withstand Voltage / Leakage Current (Battery Pack Negative Terminal vs. Housing) | This item tests the AC withstand voltage performance between the negative terminal of the battery pack and the battery housing. |
9. DC Withstand Voltage / Leakage Current (Battery Pack Positive Terminal vs. Housing) | This item tests the DC withstand voltage performance between the positive terminal of the battery pack and the battery housing. |
10. DC Withstand Voltage / Leakage Current (Battery Pack Negative Terminal vs. Housing) | This item tests the DC withstand voltage performance between the negative terminal of the battery pack and the battery housing. |
11. PACK BMS Communication – Total Voltage Reading | Reads the total battery voltage through the BMS communication interface and performs voltage range judgment. |
12. PACK BMS Communication – Cell Voltage Reading | Reads the voltage of each series string through the BMS communication interface and performs voltage range judgment on each string individually. |
13. PACK BMS Communication – Cell Voltage Difference | After acquiring cell-voltage readings, the instrument automatically identifies the maximum and minimum cell voltages and calculates their difference value. |
14. PACK BMS Communication – Maximum Cell Voltage | After acquiring cell voltage readings, the instrument automatically detects the maximum cell voltage and performs range judgment. |
15. PACK BMS Communication – Minimum Cell Voltage | After acquiring cell voltage readings, the instrument automatically detects the minimum cell voltage and performs range judgment. |
16. PACK BMS Communication – Temperature Reading | Reads the temperature collected by each temperature sensor inside the battery through the BMS communication interface and performs range judgment. |
17. PACK BMS Communication – Maximum Temperature Reading | Reads the maximum temperature collected by the temperature sensors inside the battery through the BMS communication interface and performs range judgment. |
18. PACK BMS Communication – Minimum Temperature Reading | Reads the minimum temperature collected by the temperature sensors inside the battery through the BMS communication interface and performs range judgment. |
19. PACK BMS Communication – SOC Reading | Reads the SOC value inside the battery through the BMS communication interface and performs range judgment. |
20. PACK BMS Communication – FaultStatus Reading | Reads the fault bytes inside the battery through the BMS communication interface and performs judgment. An error is reported when a fault occurs. |
21. MES System Connection | After testing is completed, the test results of this equipment can be quickly and conveniently uploaded to the MES (Manufacturing Execution System). |
Application Fields
It serves electric vehicles, buses, residential energy storage, containerized energy storage and other scenarios for end‑of‑line testing and quality control of battery modules and packs.

(DUT illustration – for reference only)
No. | Test Function |
1 | Open-Circuit Voltage (OCV) |
2 | AC Internal Resistance (ACIR) |
3 | AC Withstand Voltage, DC Withstand Voltage, and Insulation Resistance Test |
4 | Leakage Current Test |
5 | PACK Total Voltage, Cell Voltage and SOC Test |
6 | Charge-Discharge Function Test |
7 | Interlock Status Test |
8 | Temperature Sensor Test |
9 | Fault Query and Fault Clearance |
10 | PACK BMS Communication |
11 | Local Data Storage |
12 | MES System Connection |
Host PC Software
Software Architecture
The host PC software architecture is shown below. Built upon a modular‑design concept, the software consists of five core modules. It features a simple, intuitive interface for straightforward navigation; users can easily browse and switch among different functional modules. The host software is built on the ASP.NET platform, delivering high stability, reliability and scalability.

Login Interface
The login interface supports three languages: Simplified Chinese, Traditional Chinese, and English. User management covers three user roles, each with distinct operational permissions, defined as follows:
(1) Operator: Can operate the test interface, view data summaries, and access the database. This access level permits only basic operations and viewing test results; parameter configuration and similar operations are not permitted.
(2) Technician: May operate the test interface, view data summaries, access the database, configure test‑profile parameters, set serial‑communication parameters, and reset operator and technician passwords.
(3) Administrator: Provides access to a manufacturer‑reserved debugging interface for parameter review during abnormal equipment operation.

Main Interface (Test Interface)
Once parameters are configured and saved, the system automatically switches to the test interface. On this interface, users can select different test recipes for batteries across various models and batches. Once a recipe is selected, users click Start Test; the system runs the test automatically and displays test results as shown below. The system halts the test and triggers an alarm if invalid readings are obtained or faults such as reversed‑battery polarity are detected. Users may click Stop Test or activate the emergency‑stop button under urgent conditions.


Product Dimensions
Model | ACEOL 81000 | ||||||
Equipment Power | 2.5KW | ||||||
AC Input Interface | 1. Input: single-phase AC 220V±10% | ||||||
2. Input current: max. 11A | |||||||
3. Frequency: 50Hz | |||||||
Voltage Measurement Range | 0 ~ +1000V | ||||||
Voltage Accuracy | 0.01% | ||||||
Withstand Voltage Test Parameters | AC Withstand Voltage Test | 0.05KV~5KV;0.001mA~10mA | |||||
DC Withstand Voltage Test | 0.05KV~6KV;0.1uA~5mA | ||||||
Test Accuracy | ±2.0% of reading | ||||||
Insulation Resistance Test Parameters | Test Voltage | +50V~+1200V , Accuracy:±0.5%FS | |||||
0.001MΩ≦R<10MΩ | Accuracy:±(2% of reading+0.003MΩ) | ||||||
10MΩ≦R<100MΩ | Accuracy:±(2% of reading+0.03MΩ) | ||||||
100MΩ≦R<1GΩ | Accuracy:±(2% of reading+0.3MΩ) | ||||||
1GΩ≦R<5GΩ | Accuracy:±(2% of reading+3MΩ) | ||||||
R≥5GΩ | Accuracy:±(10% of reading+30MΩ) | ||||||
AC Internal Resistance (ACIR) Test Accuracy | Range | Max. Reading | Accuracy (Slow) | Resolution | Test Current | ||
1 | 3mΩ | 3.2000mΩ | 0.5%+0.04%FS | 0.1μΩ | 100mA | ||
2 | 30mΩ | 32.000mΩ | 0.5%+0.02%FS | 1μΩ | 100mA | ||
3 | 300mΩ | 320.00mΩ | 0.3%+0.02%FS | 10μΩ | 10mA | ||
4 | 3Ω | 3.2000 Ω | 0.3%+0.02%FS | 100μΩ | 1mA | ||
5 | 30Ω | 32.000 Ω | 0.3%+0.02%FS | 1 mΩ | 100μA | ||
6 | 300Ω | 320.00 Ω | 0.3%+0.02%FS | 10 mΩ | 10μA | ||
7 | 3kΩ | 3100.0Ω | 0.3%+0.02%FS | 100 mΩ | 10μA | ||
AC Internal Resistance (ACR) Test Method | 4-wire measurement | ||||||
Data Saving Method | 1. Data saved as CSV files | ||||||
2. Saved in database; query and traceability by barcode, recipe and date | |||||||
Communication Interface | Serial port RS232 (device to PC) | ||||||
Power-off Protection | After an unexpected AC input power failure, automatically disconnects the electrical connection between the battery and the equipment. | ||||||
Emergency Stop Function | Pressing the emergency stop disconnects the electrical connection between the battery and the equipment and turns off the equipment load power. | ||||||
Cooling Method | Forced air cooling | ||||||
Dimensions (W×D×H) | 680*850*1710mm | ||||||
Environment | -20℃~50℃ | ||||||
Humidity | 10-90%RH | ||||||
* Due to layout limitations, only best‑selling models are shown.Contact us for a complete product selection.