Home You are here: Home - Products - EOL Test System - EOL Test System

AC80000 Series
PACK EOL Comprehensive Test System

The EOL Comprehensive Test System is used to test comprehensive performance, such as insulation withstand voltage and BMS communication, of finished and semi-finished battery packs. The host PC software is developed on the ASP.NET platform. Featuring powerful data processing capabilities and high stability, it saves test data to the database in real time and uploads the data to the MES system.

Applications:

It serves electric vehicles, buses, residential energy storage, containerized energy storage and other scenarios for end‑of‑line testing and quality control of battery modules and packs.

Product Features

• Modular overall design for high stability and reliability, with ease of maintenance and upgrades

• A high‑performance ARM main‑control chip ensures smooth and stable device operation.

• The host PC software features a concise, clear user interface. The test step sequence is editable, and test parameters are adjustable.

• It delivers high sampling accuracy for voltage and current, paired with excellent long‑term stability.

• Supports 1D barcodes and QR codes; test initiation is available via barcode scanning or foot‑switch trigger.

• Test data can be saved automatically. The robust database enables efficient quality traceability.


Features & Benefits

Basic Test Flow

image.png


Product Design Block Diagram

image.png


System Test Items

Basic Functions

1. Open-Circuit Voltage (OCV)

The battery-pack voltage measured by the instrument while the battery pack is neither charged nor discharged.

2. AC Internal Resistance (ACIR)

The battery AC internal resistance is measured using the four-wire method. A sinusoidal current signal (1 kHz, ≤100 mA constant current) is injected through the positive and negative terminals of the battery pack, and the AC impedance is accurately measured through voltage sampling, rectification, filtering, and related processing.

3. Trigger Start

Connect to the production line or other equipment. After the PLC or control board at the line's master control end issues a start command, the EOL test system begins operation.

4. Scan-to-Start (Barcode Recording)

Start the equipment by scanning 1D or 2D barcodes to enhance convenience and smart operation. The scanned barcode is saved to the database together with the test results for later query and traceability.

5. Insulation Resistance (Battery Pack Positive Terminal vs. Housing)

Insulation resistance refers to the resistance between the live part and the exposed part of the DUT. To avoid leakage accidents, the insulation test voltage must be high enough. This item tests the insulation resistance between the battery pack positive terminal and the battery housing.

6. Insulation Resistance (Battery Pack Negative Terminal vs. Housing)

This item tests the insulation resistance between the battery pack negative terminal and the battery housing.

7. AC Withstand Voltage / Leakage Current (Battery Pack Positive Terminal vs. Housing)

Excessively high leakage current may cause electric shock hazards to personnel. Withstand voltage and leakage current testing is a critical safety test item.

Test Principle: Apply high voltage to the unit under test and detect the resulting leakage current. The withstand voltage and leakage current performance complies with specifications if the measured leakage current falls within the specified limits.

This item evaluates the AC withstand voltage performance between the positive terminal of the battery pack and the battery housing.

8. AC Withstand Voltage / Leakage Current (Battery Pack Negative Terminal vs. Housing)

This item tests the AC withstand voltage performance between the negative terminal of the battery pack and the battery housing.

9. DC Withstand Voltage / Leakage Current (Battery Pack Positive Terminal vs. Housing)

This item tests the DC withstand voltage performance between the positive terminal of the battery pack and the battery housing.

10. DC Withstand Voltage / Leakage Current (Battery Pack Negative Terminal vs. Housing)

This item tests the DC withstand voltage performance between the negative terminal of the battery pack and the battery housing.

11. PACK BMS Communication – Total Voltage Reading

Reads the total battery voltage through the BMS communication interface and performs voltage range judgment.

12. PACK BMS Communication – Cell Voltage Reading

Reads the voltage of each series string through the BMS communication interface and performs voltage range judgment on each string individually.

13. PACK BMS Communication – Cell Voltage Difference

After acquiring cell-voltage readings, the instrument automatically identifies the maximum and minimum cell voltages and calculates their difference value.

14. PACK BMS Communication – Maximum Cell Voltage

After acquiring cell voltage readings, the instrument automatically detects the maximum cell voltage and performs range judgment.

15. PACK BMS Communication – Minimum Cell Voltage

After acquiring cell voltage readings, the instrument automatically detects the minimum cell voltage and performs range judgment.

16. PACK BMS Communication – Temperature Reading

Reads the temperature collected by each temperature sensor inside the battery through the BMS communication interface and performs range judgment.

17. PACK BMS Communication – Maximum Temperature Reading

Reads the maximum temperature collected by the temperature sensors inside the battery through the BMS communication interface and performs range judgment.

18. PACK BMS Communication – Minimum Temperature Reading

Reads the minimum temperature collected by the temperature sensors inside the battery through the BMS communication interface and performs range judgment.

19. PACK BMS Communication – SOC Reading

Reads the SOC value inside the battery through the BMS communication interface and performs range judgment.

20. PACK BMS Communication – FaultStatus Reading

Reads the fault bytes inside the battery through the BMS communication interface and performs judgment. An error is reported when a fault occurs.

21. MES System Connection

After testing is completed, the test results of this equipment can be quickly and conveniently uploaded to the MES (Manufacturing Execution System).

Application Fields

It serves electric vehicles, buses, residential energy storage, containerized energy storage and other scenarios for end‑of‑line testing and quality control of battery modules and packs.

(DUT illustration – for reference only)


No.

Test Function

1

Open-Circuit Voltage (OCV)

2

AC Internal Resistance (ACIR)

3

AC Withstand Voltage, DC Withstand Voltage, and Insulation Resistance Test

4

Leakage Current Test

5

PACK Total Voltage, Cell Voltage and SOC Test

6

Charge-Discharge Function Test

7

Interlock Status Test

8

Temperature Sensor Test

9

Fault Query and Fault Clearance

10

PACK BMS Communication

11

Local Data Storage

12

MES System Connection

Host PC Software

Software Architecture

The host PC software architecture is shown below. Built upon a modular‑design concept, the software consists of five core modules. It features a simple, intuitive interface for straightforward navigation; users can easily browse and switch among different functional modules. The host software is built on the ASP.NET platform, delivering high stability, reliability and scalability.




image.png

Login Interface

The login interface supports three languages: Simplified Chinese, Traditional Chinese, and English. User management covers three user roles, each with distinct operational permissions, defined as follows:

(1) Operator: Can operate the test interface, view data summaries, and access the database. This access level permits only basic operations and viewing test results; parameter configuration and similar operations are not permitted.

(2) Technician: May operate the test interface, view data summaries, access the database, configure test‑profile parameters, set serial‑communication parameters, and reset operator and technician passwords.

(3) Administrator: Provides access to a manufacturer‑reserved debugging interface for parameter review during abnormal equipment operation.


image.png

Main Interface (Test Interface)

Once parameters are configured and saved, the system automatically switches to the test interface. On this interface, users can select different test recipes for batteries across various models and batches. Once a recipe is selected, users click Start Test; the system runs the test automatically and displays test results as shown below. The system halts the test and triggers an alarm if invalid readings are obtained or faults such as reversed‑battery polarity are detected. Users may click Stop Test or activate the emergency‑stop button under urgent conditions.

image.png

image.png


Dimensions

Product Dimensions

Model

ACEOL 81000

Equipment Power

2.5KW

AC Input Interface

1. Input: single-phase AC 220V±10%     

2. Input current: max. 11A         

3.  Frequency:  50Hz                                 

Voltage Measurement Range

0 ~ +1000V  

Voltage Accuracy

0.01%

Withstand Voltage Test Parameters

AC Withstand Voltage Test

0.05KV~5KV;0.001mA~10mA

DC Withstand Voltage Test

0.05KV~6KV;0.1uA~5mA

Test Accuracy

±2.0% of reading

Insulation Resistance Test Parameters

Test Voltage

+50V~+1200V , Accuracy:±0.5%FS

0.001MΩ≦R<10MΩ

Accuracy:±(2% of reading+0.003MΩ)

10MΩ≦R<100MΩ

Accuracy:±(2% of reading+0.03MΩ)

100MΩ≦R<1GΩ

Accuracy:±(2% of reading+0.3MΩ)

1GΩ≦R<5GΩ

Accuracy:±(2% of reading+3MΩ)

R≥5GΩ

Accuracy:±(10% of reading+30MΩ)

AC Internal Resistance (ACIR) Test Accuracy

Range

 Max. Reading

Accuracy (Slow)

Resolution

Test Current

1

3mΩ

3.2000mΩ

0.5%+0.04%FS

0.1μΩ

100mA

2

30mΩ

32.000mΩ

0.5%+0.02%FS

1μΩ

100mA

3

300mΩ

320.00mΩ

0.3%+0.02%FS

10μΩ

10mA

4

3Ω

3.2000 Ω

0.3%+0.02%FS

100μΩ

1mA

5

30Ω

32.000 Ω

0.3%+0.02%FS

1 mΩ

100μA

6

300Ω

320.00 Ω

0.3%+0.02%FS

10 mΩ

10μA

7

3kΩ

3100.0Ω

0.3%+0.02%FS

100 mΩ

10μA

AC Internal Resistance (ACR) Test Method

4-wire measurement

Data Saving Method

1. Data saved as CSV files

2. Saved in database; query and traceability by barcode, recipe and date

Communication Interface

Serial port RS232 (device to PC)

Power-off Protection

After an unexpected AC input power failure, automatically disconnects the electrical connection between the battery and the equipment.

Emergency Stop Function

Pressing the emergency stop disconnects the electrical connection between the battery and the equipment and turns off the equipment load power.

Cooling Method

Forced air cooling

Dimensions (W×D×H)

680*850*1710mm

Environment

-20℃~50℃

Humidity

10-90%RH

* Due to layout limitations, only best‑selling models are shown.Contact us for a complete product selection.