The thermal management system of new energy vehicles ensures vehicle temperature control safety. Electric compressors and PTC heaters are core components. Their operating stability, energy consumption, and various protection functions directly affect driving experience and battery safety. Comprehensive electrical performance verification is required during product development and production line stages. Compressor and PTC testing for new energy vehicles requires an integrated verification system with high-voltage safety isolation, synchronized multi-physical parameter acquisition, and precise, controllable condition simulation, covering electrical performance, thermal management efficiency, control logic, safety compliance and durability.
Electric Compressor Test for New Energy Vehicles
Electric Compressor Test – Precautions for Using High-Voltage DC Power Supplies
• Key Differences versus PTC
A compressor is an inductive load with a motor inverter; energy feedback occurs during load reduction or shutdown. Compressors are highlysusceptible to DC bus voltage pump-up and overvoltage damage. It applies to 400 V/800 V electric scroll compressors (R134a/R1234yf/CO₂ heat pumps)and complies with Q/T 1075-2023 and GB/T 22068 standards.
• Selection Considerations
Bidirectional regenerative power supplies are recommended. When the compressor decelerates, unloads, or shuts down, the motor generates power and feeds energy back to the DC bus. A unidirectional programmable DC power supply cannot absorb regenerative energy, causing the bus voltage to rise rapidly, triggering OVP and severely damaging the compressor controller IGBT. If a unidirectional power supply solution must be adopted, a high-power brake discharge resistor must be installed.
PTC Test for New Energy Vehicles
PTC components exhibit extremely low cold‑state resistance; the power‑on inrush current is far higher than the steady‑state current. Power supply selection cannot be based solely on steady-state power; peak margin must be reserved. For R&D benches, programmable regenerative bidirectional DC power supplies (battery simulators) are preferred. For production lines, standard programmable high-voltage DC power supplies may be used.
Basic Range Requirements
• Voltage Coverage
400 V platform: 0–500 V, supporting low-voltage 250 V, rated 400 V, and overvoltage 450 V testing.
800 V platform: 0–900 V (0–1000 V recommended), covering the complete 250–850 V operating range.
Must support continuously adjustable constant voltage (CV) / constant current (CC) modes and voltage sweep testing.
• Power & Current Margin (Critical)
Steady-state power: typically 2 kW–10 kW (cabin / battery water-heating PTC).
Cold-start inrush current: 2–3 times the steady-state current, lasting tens to hundreds of milliseconds. The power supply's peak output capability must cover this; otherwise, power-on current limiting, data distortion, or even misjudgment of PTC faults may occur.
• Selection Guidelines
Power supply rated power ≥ PTC steady-state power × 1.5; peak current ≥ steady-state current × 3.
Low-voltage auxiliary power supply (essential for PTC with integrated controller, independent channel):
12 V system: 9–16 V continuously adjustable; 24 V system: 16–32 V.
Compliant with ISO 16750-2: voltage drop, fluctuation, reverse connection, and surge testing. Automotive power simulators are recommended; basic ordinary adapters are prohibited.
Accuracy, Ripple, and Dynamic Characteristics (for Accurate Power Measurement)
• Output Accuracy
Voltage accuracy ≤ ±0.05% FS; current accuracy ≤ ±0.1% FS; mV/mA-level resolution, meeting the power measurement requirements of QC/T 1101 and T/CAAMTB 132.
• Ripple and Noise
High-frequency ripple: ≤0.05% FS (20 MHz bandwidth), low-noise output. Excessive ripple can cause power analyzer reading drift, CAN communication interference, and EMC test misjudgment.
• Dynamic Response
Step response < 2–5 ms. The response speed must be sufficient to follow the controller's switching speed in real time, with no significant overshoot or ringing during loading/unloading. It supports custom voltage waveforms to simulate vehicle bus fluctuations and regenerative surges (battery simulator function).
Wide Range and Auto-Ranging
• Auto-ranging power supplies are recommended to cover both low-voltage/high-current (cold start) and high-voltage/low-current conditions, enabling a single unit to cover PTC testing across multiple specifications.
BESCO provides professional Compressor & PTC test solutions equipped with high‑accuracy programmable DC power supplies and other instruments. The system simulates various vehicle power supply conditions and conducts verification items including energy efficiency test, steady‑state and dynamic operation, overvoltage/undervoltage, overcurrent, and overtemperature protection. It complies with relevant standard test requirements and safely and efficiently validates performance and reliability of compressors and PTC heaters under diverse extreme operating conditions in both laboratory and production line environments, ensuring stable operation of new energy vehicle thermal management systems.